The undersigned hereby assign all rights, included but not limited to copyright, for this manuscript to CMB Association upon its submission for consideration to publication on Cellular and Molecular Biology. The rights assigned include, but are not limited to, the sole and exclusive rights to license, sell, subsequently assign, derive, distribute, display and reproduce this manuscript, in whole or in part, in any format, electronic or otherwise, including those in existence at the time this agreement was signed. The authors hereby warrant that they have not granted or assigned, and shall not grant or assign, the aforementioned rights to any other person, firm, organization, or other entity. All rights are automatically restored to authors if this manuscript is not accepted for publication.
Optimization of (131)I doses for the treatment of hyperthyroidism
Corresponding Author(s) : F. Araujo
faraujo@ird.gov.br
Cellular and Molecular Biology,
Vol. 55 No. 3: First symposium on internal dosimetry applied to nuclear medicine (DOSIMN) 2008 Part 1
Abstract
Several methods can be used to determine the activity of 131I in the treatment of hyperthyroidism. However, many of them do not consider all the parameters necessary for optimum dose calculation. The relationship between the dose absorbed by the thyroid and the activity administered depends basically on three parameters: organ mass, iodine uptake and effective half-life of iodine in the thyroid. Such parameters should be individually determined for each patient in order to optimize the administered activity. The objective of this work is to develop a methodology for individualized treatment with 131I in patients with hyperthyroidism of the Grave's Disease. A neck-thyroid phantom developed at the IRD was used to calibrate a scintillation camera and a uptake probe SCT-13004 at the Nuclear Medicine Center of the University Hospital of Rio de Janeiro and a uptake probe SCT-13002, available at the Nuclear Medicine Institute in Goií¢nia. The biokinetic parameters were determined based on measurements performed in eight voluntary patients. It is concluded that the use of the equipment available at the hospital (scintillation camera and uptake probe) has shown to be a suitable and feasible procedure for dose optimization in terms of effectiveness, simplicity and cost.
Keywords
Nuclear medicine
hiperthyroidism
I-131.
Araujo, F., Rebelo, A. M. O., Rebelo, A. M. O., Pereira, A. C., Moura, M. B., Lucena, E. A., Dantas, A. L. A., Dantas, B. M., & Corbo, R. (2009). Optimization of (131)I doses for the treatment of hyperthyroidism. Cellular and Molecular Biology, 55(3), 1–6. Retrieved from https://cellmolbiol.org/index.php/CMB/article/view/1018
Download Citation
Endnote/Zotero/Mendeley (RIS)BibTeX